Watts 3/4 LFN45BM1-U Pressure Reducing Valve, 3/4 in NPT x NPT Female, 25 to
Series LFN45B lead-free water pressure reducing valves are used in commercial and residential applications to reduce incoming water pressure to a predetermined level, thereby protecting downstream plumbing system components and reducing water consumption. Designed for easy accessibility and serviceability without removing the valve from the line. Standard pressure setting is 50 psi with an adjustable range of 25 to 75 psi (172 to 517 kPa).
CAMCO 10473 Relief Valve, 3/4 in NPT, 150 psi Operating, Brass
CAMCO's 3/4 in temperature and pressure valve with 4 in probe will help protect your RV or home water heater from excessive temperature and water pressure. It's factory set at 150 psi and 210 deg F. It features epoxy-coated probe to prevent corrosion buildup.
1/2" x 15mm - Temperature & Pressure Relief Valve - Short Probe
Prevents damage to heating systems by relieving excess pressure and temperature
1/2" MBSP x 15mm compression connections
Set discharge pressure: 10 bar
Factory set discharge temperature: 90?C - non-adjustable
Max working temperature: 80?C
Short 100mm probe
DRZ brass body
These Temperature and Pressure relief valves (T & P) are designed to discharge excess pressure which builds up inside sealed systems during the heating cycle. If the water inside the cylinder reaches above 90?C the T & P valve will discharge the hot water protecting the cylinder and components from excessive temperatures. During normal operating conditions nothing will be discharged from the valve.
Apollo 36 Series, PR Pressure Reducing Valve, 3/4 in, Single Union NPT, 25
Apollo(TM) Pressure Reducing Valve, Series: 36 Series, 3/4 in Nominal, Single Union NPT, 25 to 75 psig, 33 to 180 deg F, Media: Water, 5-5/8 in Inlet to Outlet Length, Bronze Body, Brass Trim, Nitrile O-Ring Softgoods, 5-7/8 in H x 2-3/4 in D, Domestic
Apollo(R) Model PR (36 Series) Pressure Reducing Valves are designed to protect residential and commercial water distribution systems by controlling excessive pressures. The valves are built for long reliable service with proven ASTM grade materials including a bronze body and stainless steel strainer.
Apollo 36 Series, PR Pressure Reducing Valve, 1 in, Single Union NPT, 25 to
Apollo(TM) Pressure Reducing Valve, Series: 36 Series, 1 in Nominal, Single Union NPT, 25 to 75 psig, 33 to 180 deg F, Media: Water, 6-3/8 in Inlet to Outlet Length, Bronze Body, Brass Trim, Nitrile O-Ring Softgoods, 6-7/8 in H x 3-3/8 in D, Domestic
Apollo(R) Model PR (36 Series) Pressure Reducing Valves are designed to protect residential and commercial water distribution systems by controlling excessive pressures. The valves are built for long reliable service with proven ASTM grade materials including a bronze body and stainless steel strainer.
Zurn 1/2 in. No Lead Pressure Reducing Valve FNPT Union x FNPT Tool
The 1/2" 500XL Pressure Reducing Valve works effectively for industrial water lines and commercial irrigation systems with high-flow rate capacity and low falloff. The balanced piston design enables the regulator to respond seamlessly to changes in the system flow demand, ultimately providing vital protection from inlet pressure changes. The direct-acting integral bypass design prevents buildup of excessive system pressure caused by thermal expansion. The all-bronze body and threaded bell provide superior corrosion resistance and easy access to the internal system. You will save valuable installation time and labor costs.
Short lay length and compact design allow it to install in tight spaces
High-flow capacity suits commercial or industrial pressure reduction applications
Highly durable, threaded bell resists corrosion and provides easy access to cartridge internals
Lead-free
ASSEA(R) Listed
IAPMOA(R) Listed
CSAA(R) Certified
City of Los Angeles Approved
Meets the requirements of NSF/ANSI 61
Zurn Wilkins 3/4" Water Pressure Reducing Valve FNPT Union x FNPT - Lead
Ideal for use where lead free valves are required. Designed for installation on potable water lines to reduce high inlet pressure to a lower outlet pressure. The high flow capacity makes this device most suitable for industrial water lines and commercial irrigation systems. The direct acting integral by-pass design prevents buildup of excessive system pressure caused by thermal expansion. The balanced piston design enables the regulator to react in a smooth and responsive manner to changes in system flow demand, while at the same time, providing protection from inlet pressure changes.
Features:
Maximum working water pressure 300 psi
Maximum working water temperature 180? F
Reduced pressure range 25 psi to 75 psi
All bronze body and bell housing provides durability
Zurn 1 in. No Lead Pressure Reducing Valve FNPT Union x FNPT Tool
Ideal for use where Lead-Free valves are required. Designed for installation on potable water lines to reduce high inlet pressure to a lower outlet pressure. The high flow capacity makes this device most suitable for industrial water lines and commercial irrigation systems. The direct acting integral bypass design prevents buildup of excessive system pressure caused by thermal expansion. The balanced piston design enables the regulator to react in a smooth and responsive manner to changes in system flow demand, while at the same time, providing protection from inlet pressure changes.
Well suited for industrial or commercial applications
High flow rate with minimal fall-off
All bronze body and bell resist corrosion
Low-lead law compliant
Maximum working water pressure 300 psi
Maximum working water temperature 140A?F
Zurn-Wilkins 2-500XL 2 in. Lead-Free Brass FPT x FPT Water Pressure Reducing
The Zurn-Wilkins Model 500XL is the workhorse of the Wilkins pressure reducing valve line up. Exhibiting the highest flow rates of the entire Wilkins regulator line makes this device most suitable for industrial water lines and commercial irrigation systems. The low-lead law compliant valve is designed for installation on potable water lines to reduce high inlet pressure to a lower outlet pressure.
Direct acting integral by-pass design prevents buildup of excessive system pressure caused by thermal expansion
Balanced piston design enables the regulator to react in a smooth and responsive manner to changes in system flow demand, while at the same time, providing protection from inlet pressure changes
All bronze body and bell resists corrosion
High flow rate with minimal fall-off
Valve may be installed in any position and is serviceable in-line
ASSE listed 1003, IAPMO listed, CSA certified, city of Los Angeles approved, NSF listed - standard 61, annex G